Solid-state Twin Timers H3CR-F CSM_H3CR-F_DS_E_1_6 DIN 48 x 48-mm Twin Timers * Wide power supply ranges of 100 to 240 VAC and 48 to 125 VDC respectively. * ON- and OFF-times can be set independently and so combinations of long ON- or OFF-time and short OFF- or ONtime settings are possible. * Sixteen time ranges from 0.05 s to 30 h or from 1.2 s to 300 h depending on the model to be used. * Models with a flicker ON start or flicker OFF start are available. * Easy sequence checks through instantaneous outputs for a zero set value at any time range. * Length, when panel-mounted with a Socket, of 80 mm or less. * 11-pin and 8-pin models are available. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure Model Number Legend H3CR - F @ @ - @ @ 1 2 3 4 5 1. Classification F: Twin timers 2. Configuration None: 11-pin socket 8: 8-pin socket 3. Twin Timer Mode None: Flicker OFF start N: Flicker ON start 4. Time Range None: 0.05 s to 30 h models 300: 1.2 s to 300 h models 5. Supply Voltage 100-240AC: 100 to 240 VAC 24AC/DC: 24 VAC/VDC 12DC: 12 VDC 48-125DC: 48 to 125 VDC Ordering Information List of Models Operating modes Flicker OFF start Supply voltage 100 to 240 VAC 0.05 s to 30 h models 11-pin models H3CR-F 100-240AC 8-pin models 1.2 s to 300 h models 11-pin models 8-pin models H3CR-F8 100-240AC H3CR-F-300 100-240AC H3CR-F8-300 100-240AC 24 VAC/DC H3CR-F 24AC/DC H3CR-F8 24AC/DC H3CR-F-300 24AC/DC H3CR-F8-300 24AC/DC 12 VDC H3CR-F 12DC H3CR-F8 12DC H3CR-F-300 12DC H3CR-F8-300 12DC 48 to 125 VDC H3CR-F 48-125DC H3CR-F8 48-125DC H3CR-F-300 48-125DC H3CR-F8-300 48-125DC H3CR-FN 100-240AC H3CR-F8N 100-240AC H3CR-FN-300 100-240AC H3CR-F8N-300 100-240AC H3CR-F8N-300 24AC/DC Flicker ON start 100 to 240 VAC 24 VAC/DC H3CR-FN 24AC/DC H3CR-F8N 24AC/DC H3CR-FN-300 24AC/DC 12 VDC H3CR-FN 12DC H3CR-F8N 12DC H3CR-FN-300 12DC H3CR-F8N-300 12DC 48 to 125 VDC H3CR-FN 48-125DC H3CR-F8N 48-125DC H3CR-FN-300 48-125DC H3CR-F8N-300 48-125DC Note: Specify both the model number and supply voltage when ordering. Example: H3CR-F 100-240AC Supply voltage 1 H3CR-F Accessories (Order Separately) Adapter, Protective Cover and Hold-down Clip Name/specifications Models Flush Mounting Adapter Y92F-30 Y92F-73 *1 Y92F-74 *1 Y92A-48B *2 Protective Cover Hold-down Clip (Sold in sets of two) For PF085A Socket Y92H-8 For PL08 and PL11 Sockets Y92H-7 Note: Refer to H3CR-A datasheet for details. *1 The Y92F-48B Front Cover and the Y92P-48G@ Panel Cover cannot be used at the same time. *2 The Y92F-48B Front Cover is made from hard plastic. Remove the Front Cover to change the set value. The Y92F-48B Front Cover and the Y92F-73/-74 Flush Mounting Adapter also cannot be used at the same time. Sockets Timer Round Sockets Pin Connection 11-pin Front Connecting Back Connecting 8-pin Front Connecting Back Connecting Terminal Models DIN track mounting P2CF-11 DIN track mounting (Finger-safe type) P2CF-11-E Screw terminal P3GA-11 Solder terminal PL11 Wrapping terminal PL11-Q PCB terminal PLE11-0 DIN track mounting P2CF-08 DIN track mounting (Finger-safe type) P2CF-08-E DIN track mounting PF085A Screw terminal P3G-08 Solder terminal PL08 Wrapping terminal PL08-Q PCB terminal PLE08-0 Note: 1. The P2CF-@@-E has a finger-protection structure. Round crimp terminals cannot be used. Use forked crimp terminals. 2. The P3GA-11 and P3G-08 Socket can be used together with the Y92A-48G Terminal Cover to implement finger protection. 3. For details, refer to Socket and DIN Track Products. Terminal Cover Application For back connecting socket Model Y92A-48G Remarks For P3G-08 and P3GA-11 Note: For details, refer to Socket and DIN Track Products. 2 H3CR-F Specifications General Item H3CR-F H3CR-F8 H3CR-FN Operating mode Flicker OFF start Pin type 11-pin Operating/Reset method Time-limit operation/Time-limit reset or self-reset Output type Relay output (DPDT) Mounting method DIN track mounting, surface mounting, and flush mounting Approved standards UL508, CSA C22.2 No.14, NK, Lloyds Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2. Output category according to EN60947-5-1. H3CR-F8N Flicker ON start 8-pin 11-pin 8-pin Time Ranges 0.05 s to 30 h Models Time unit Setting x10 s (10 sec) s (sec) min (min) 1.2 0.05 to 1.2 1.2 to 12 0.12 to 1.2 3 0.3 to 3 3 to 30 0.3 to 3 12 1.2 to 12 12 to 120 1.2 to 12 30 3 to 30 30 to 300 3 to 30 h (hrs) Note: Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0. 1.2 s to 300 h Models Time unit Setting x10 s (10 sec) x10 min (10 min) x10 h (10 hrs) h (hrs) 1.2 1.2 to 12 1.2 to 12 0.12 to 1.2 1.2 to 12 3 3 to 30 3 to 30 0.3 to 3 3 to 30 12 12 to 120 12 to 120 1.2 to 12 12 to 120 30 30 to 300 30 to 300 3 to 30 30 to 300 Note: Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0. Ratings Rated supply voltage (See notes 1, 2, and 3.) 100 to 240 VAC (50/60 Hz),12 VDC, 24 VAC/DC (50/60 Hz), 48 to 125 VDC Operating voltage range 85% to 110% of rated supply voltage; 90% to 110% with 12-VDC models Power reset Minimum power-opening time: 0.1 s Power consumption 100 to 240 VAC: approx. 10 VA (2.1 W) at 240 VAC 24 VAC/VDC: approx. 2 VA (1.7 W) at 24 VAC approx. 1 W at 24 VDC 48 to 125 VDC: approx. 1.5 W at 125 VDC 12 VDC: approx. 1 W at 12 VDC Control outputs Contact output: 5 A at 250 VAC/30 VDC, resistive load (cos = 1) Note: 1. A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each DC Model. 2. Do not use an inverter output as the power supply. Refer to Safety Precautions for All Timers for details. 3. Refer to Safety Precautions for All Timers when using the Timer together with a 2-wire AC proximity sensor. 3 H3CR-F Characteristics Accuracy of operating time 0.2% FS max. (0.2% FS 10 ms max. in ranges of 1.2 and 3 s) Setting error 5% FS 50 ms max. Reset time 0.1 s max. Reset voltage 10% max. of rated voltage Influence of voltage 0.2% FS max. (0.2% FS 10 ms max. in ranges of 1.2 and 3 s) Influence of temperature 1% FS max. (1% FS 10 ms max. in ranges of 1.2 and 3s) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts) 2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit) 2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities) 1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other) Impulse withstand voltage 3 kV (between power terminals) for 100 to 240 VAC, 48 to 125 VDC 1 kV for 12 VDC, 24 VAC/DC 4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC, 48 to 125 VDC 1.5 kV for 12 VDC, 24 VAC/DC Noise immunity 1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) 400 V for 12 VDC Static immunity Malfunction: 8 kV Destruction: 15 kV Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions Malfunction: 10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions Shock resistance Destruction: 980 m/s2 three times each in six directions Malfunction: 98 m/s2 three times each in six directions Ambient temperature Operating: Storage: -10C to 55C (with no icing) -25C to 65C (with no icing) Ambient humidity Operating: 35% to 85% Life expectancy Mechanical: 20 million operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) (See note) EMC (EMI) Emission Enclosure: Emission AC Mains: (EMS) Immunity ESD: EN61812-1 EN55011 Group 1 class A EN55011 Group 1 class A EN61812-1 IEC61000-4-2: 6 kV contact discharge (level 3) 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: IEC61000-4-3: 10 V/m (9005 MHz) (level 3) Immunity Conducted Disturbance: IEC61000-4-6: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: IEC61000-4-4: 2 kV power-line (level 3) 2 kV I/O signal-line (level 4) Immunity Surge: IEC61000-4-5: 1 kV line to line (level 3) 2 kV line to ground (level 3) Case color Light Gray (Munsell 5Y7/1) Degree of protection IP40 (panel surface) Weight Approx. 100 g Note: Refer to the Life-test Curve. 4 H3CR-F Life-test Curve Switching operations (x 103) 10,000 5,000 1,000 500 Reference: A maximum current of 0.15 A can be switched at 125 VDC (cos = 1) and a maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 10 mA at 5 VDC (failure level: P). 30 VDC L/R = 7 ms 250 VAC/30 VDC (cos = 1) 100 250 VAC (cos = 0.4) Load current (A) Connections Block Diagrams ON indicator Zero setting detection circuit OFF indicator Indicator circuit ROM RAM Clock Output circuit AC (DC) input Power supply circuit Time range/unit selectors One-chip microcomputer I/O Functions Inputs Outputs --Control output Outputs are turned ON/OFF according to the time set by the ON- and OFF-time setting knob. Terminal Arrangement H3CR-F8 H3CR-F8N H3CR-F8-300 H3CR-F8N-300 H3CR-F H3CR-FN H3CR-F-300 H3CR-FN-300 (+)(~) Power supply Power supply Note: Leave terminals 5, 6, and 7 open. Do not use them as relay terminals. 5 H3CR-F Operation Timing Chart tON: ON set time tOFF: OFF set time Operating mode Timing chart Flicker OFF start 0.1 s min Power - - ON OFF ONindicator Lit Not lit OFF indicator Lit Not lit tOFF tON tOFF tON tOFF tOFF Output NO - - ON - - OFF Output NC - - ON - - OFF Flicker ON start 0.1 s min. Power - - ONindicator ON OFF tON tOFF tON tOFF tON tOFF Lit Not lit OFF indicator Lit Not lit Output NO ON - - - - OFF Output NC - - ON - - OFF Note: 1. The reset time requires a minimum of 0.1 s. 2. When power is supplied in flicker ON start mode, the OFF indicator lights momentarily. This, however, has no effect on the performance of the Timer. Nomenclature OFF indicator (green) Lit when the output is OFF. ON indicator (orange) Lit when the output is ON. Scale range display windows OFF-time unit display window OFF-time unit selector (select one from sec. 10 s, min., and hrs, or from 10 s, 10 min, hrs, and 10 h) ON-time setting knob (with orange pointer) For ON-time setting OFF-time setting knob (with green pointer) For OFF-time setting Time range selector (select one from 1.2, 3, 12, and 30 at full scale) For both ON-time and OFF-time. ON-time unit display window ON-time unit selector (select one from sec, 10 s, min, and hrs, or from 10 s, 10 min, hrs, and 10 h) 6 H3CR-F Dimensions Note: All units are in millimeters unless otherwise indicated. H3CR-F H3CR-FN H3CR-F-300 H3CR-FN-300 17.4 5.7 6 48 66.6 52.3 44.8 x 44.8 37 dia. 48 0.7 14 dia. R1.3 11 pins H3CR-F8 H3CR-F8N H3CR-F8-300 H3CR-F8N-300 17.4 5.7 6 48 66.6 52.3 44.8 x 44.8 37 dia. 48 0.7 14 dia. R1.3 8 pins Dimensions with Flush Mounting Adapter Y92F-30 Flush Mounting Adapter (Order Separately) Panel P3G Back Connecting Socket (Order separately) Mounting Hole Dimensions (Conform to DIN 43700.) 0.5 R max. 58 45+0.6 -0 (N) 52 45+0.6 -0 42 48 Note: 1. The orientation of the Adapters for two or more Timers is different for a horizontal or vertical layout. Make sure the orientation is correct. Consecutive Mounting of n Timers Without Front Covers: N = (48n - 2.5) + 1 - 0 With Front Covers: N = (51n - 5.5) + 1 - 0 With Panel Covers: N = (50n - 4.5) + 1 - 0 2. The mounting panel thickness must be 1 to 5 mm. Y92F-73 Flush Mounting Adapter (Order Separately) Panel Adapter mounting holes: Two, 4.5 d P3G Back Connecting Socket 52 to 53 0.5 R max. 65 to 66 88 450.15 760.2 Insert the Timer in this direction.* 450.15 58 Note: A Front Cover and Panel Cover cannot be used at the same time. 52.3 Note: The mounting panel thickness must be 1 to 3.2 mm. * Insert the Timer from the back of the Adapter. 7 H3CR-F Y92F-74 Flush Mounting Adapter (Order Separately) Panel 56 P3G Back Connecting Socket 58 450.2 0.5 R max. 45+0.5 -0 55+0.5 -0 68 430.2 50+0.2 0 52.3 Note: A Front Cover and Panel Cover cannot be used at the same time. Dimensions with Front Connecting Socket P2CF-08-@/P2CF-11-@ Note: The mounting panel thickness must be 1 to 3.2 mm. Dimensions with Back Connecting Socket P3G-08/P3GA-11 17.4 81.5 80 H3CR-F H3CR-FN 103.2* H3CR-F8 H3CR-F8N 100.9 92.3* 90.0 H3CR-F H3CR-FN + Adapter Y92F-30 2.3* 2.3* P2CF-11 P2CF-08 P2CF-11-E P2CF-08-E * These dimensions vary with the kind of DIN track (reference value). P3GA-11 (When Y92A-48G mounted) 17.4 81.5 75 H3CR-F8 H3CR-F8N + Adapter Y92F-30 P3G-08 (When Y92A-48G mounted) Note: There are no restrictions to the mounting direction. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 8 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2012.8 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2012 All Right Reserved.